CLEAN BURN CB-2800 Service Manual Page 37

  • Download
  • Add to my manuals
  • Print
  • Page
    / 79
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 36
ES526/EX536/EX531/CB2800/ES526L/EX536L/DS316L
Condential
4-6
1. Frequency and tracking boundary
Procedure - Test equipment: video generator
- Test signal: analog 800 x 600 @60Hz
- Test pattern: general-1 or master
- Check and see if the image sharpness is well
performed.
- If not, re-adjust by the following steps:
(1) Select "Frequency" function to adjust the total
pixel number of pixel clock in one line period.
(2) Select "Tracking" function and use right or left
arrow key to adjust the value to minimize video
icker.
- Adjust Resync or Frequency/Tracking/H Image
Shift/V Image Shift to the inner screen.
Inspection item - Eliminate visual wavy noise by Rsync, Frequency
or Tracking selection.
- Check if there is noise on the screen.
- Horizontal and vertical position of the video should
be adjustable to the screen frame.
Criteria - If there is noise on the screen, the product is
considered as failure product.
- If there is noise on the screen, use auto or manual “frequen-
cy” function or “tracking” function to adjust the screen.
- The PC mode functionally sure be workable include support
format with frequency and auto detected functional will be
workable.
2. Light Leak
Procedure - Test equipment: video generator
- Test signal: analog 800 x 600 @60Hz
- Test pattern: Black pattern
- Check if the light leaks.
* Light leak on reective edge, eye-catcher, bond
wires and exposed metal.
Inspection item - Light leak check.
Criteria - The pattern cannot accept the color level of the
General-1
Full black
Master
Page view 36
1 2 ... 32 33 34 35 36 37 38 39 40 41 42 ... 78 79